Load Centers, Meters and Electrical Enclosures
-
Loadcenters and Panelboards
-
Meter Sockets
-
Electrical Enclosures
-
Energy Meters
-
Power Outlet Panels
-
Accessories for Panels & Enclosures
- Product
- Qty in Cart
- Price
-
Contact Us For Quote
Eaton BRP20N200R Loadcenters and Panelboards
MSRP $503.72Surplus $136.01SKU: L19-6663 Brand: Eaton MPN: BRP20N200R UPC: 78668905929 Shipping Weight: 0.00 lbs. Shipping Height: 0.00 In. Shipping Length: 0.00 In. Shipping Width: 0.00 In...- SKU:
- L19-6663
- Circuit Configuration:
- 1-Phase 3-Wire
- Short Description:
- 120/240 VAC, 1-Phase, 200 A, 10 kA, 3-Wire, 40-Circuit, 20-Space, X5R Enclosure Size Designation, NEMA 3R, Outdoor, Gray Trim, Tin Plated Aluminum Bus, Insulated/Bondable Split Plug-On Neutral, Convertible, Load Center
- Enclosure Size Designation:
- X5R
- Bus Material:
- Tin Plated Aluminum
- Maximum Number of Circuits:
- 40
- Main Breaker Type:
- BR
- Interrupting Rating:
- 10 kA
- Breaker Mounting:
- Plug-On
- Type:
- Convertible
- Current Rating:
- 200 A
- Size:
- 15.5 Inch Width x 30.5 Inch Depth x 5.8 Inch Height
- Catalog:
- Eaton_00071_V1T1_46-V1T1_49_V1T1_55_CAT.pdf
- Maximum Number of Spaces:
- 20
- Neutral Type:
- Insulated/Bondable Split
- Feed Location:
- Top/Bottom
- Voltage Rating:
- 120/240 VAC
- Enclosure Type:
- NEMA 3R, Outdoor
- Approval:
- UL 50/67
MSRP $503.72Surplus $136.01 -
Contact Us For Quote
Eaton BRP20NC125 Loadcenters and Panelboards EA
MSRP $955.65Surplus $258.03SKU: L19-5642 Brand: Eaton MPN: BRP20NC125 UPC: 786689053314 Shipping Weight: 22.40 lbs. Shipping Height: 5.00 In. Shipping Length: 25.00 In. Shipping Width: 16.00 In...- SKU:
- L19-5642
- TS PIK:
- 127538915
- Series:
- BR
- Short Description:
- Eaton BR convertible loadcenter,Convertible,125 A,X3,Copper,Cover included,NEMA 1,Metallic,10 kAIC,BR,Combination,40 Circuits,Single-pole,20 Spaces,Two hots, a neutral, and a ground,Single-phase,Type BR 1-inch breakers,120/240 V
- Maximum Number of Circuits:
- 40
- Current Rating:
- 125 A
- Type:
- Convertible
- Country of Origin:
- United States
MSRP $955.65Surplus $258.03 -
Contact Us For Quote
Eaton BRP20NC200R Loadcenters and Panelboards
MSRP $1,180.97Surplus $318.86SKU: L19-6677 Brand: Eaton MPN: BRP20NC200R UPC: 78668905933 Shipping Weight: 0.00 lbs. Shipping Height: 0.00 In. Shipping Length: 0.00 In. Shipping Width: 0.00 In...- SKU:
- L19-6677
- Feed Location:
- Top/Bottom
- Size:
- 15.8 Inch Width x 30.6 Inch Depth x 5.8 Inch Height
- Breaker Mounting:
- Plug-On
- Enclosure Type:
- NEMA 3R, Outdoor
- Voltage Rating:
- 120/240 VAC
- Maximum Number of Spaces:
- 20
- Bus Material:
- Copper
- Neutral Type:
- Insulated/Bondable Split
- Main Breaker Type:
- BR
- Enclosure Size Designation:
- X5R
- Catalog:
- Eaton_00071_V1T1_46-V1T1_49_CAT.pdf
- Short Description:
- 120/240 VAC, 1-Phase, 200 A, 10 kA, 3-Wire, 40-Circuit, 20-Space, X5R Enclosure Size Designation, NEMA 3R, Outdoor, Gray Trim, Copper Bus, Insulated/Bondable Split Plug-On Neutral, Convertible, Load Center
- Maximum Number of Circuits:
- 40
- Approval:
- UL 50/67
- Circuit Configuration:
- 1-Phase 3-Wire
- Type:
- Convertible
- Interrupting Rating:
- 10 kA
- Current Rating:
- 200 A
MSRP $1,180.97Surplus $318.86 -
Contact Us For Quote
Eaton CH40SPAST Loadcenters and Panelboards CH 40A 120V 50/60Hz 1Ph 3Wire 40Cir NEMA 3R Used w/ SPA PANEL
MSRP $940.00Surplus $380.67SKU: L19-1624 Brand: Eaton MPN: CH40SPAST UPC: 786685969886 Shipping Weight: 7.40 lbs. Shipping Height: 5.00 In. Shipping Length: 13.00 In. Shipping Width: 8.00 In...- SKU:
- L19-1624
- Approval:
- UL
- Size:
- 4.5 Inch Width x 3.13 Inch Depth x 9.5 Inch Height
- Volts:
- 120/240 VAC
- Amps:
- 40 A
- Enclosure:
- NEMA 3R
- Enclosure:
- Outdoor
- Neutral Type:
- Insulated/Bondable Split
- Circuit Configuration:
- 1-Phase 3-Wire
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 5R
- Maximum Number of Spaces:
- 3/4 Inch
- Main Wire Size:
- 14 to 1/0 AWG Copper/Aluminum
- Catalog:
- Eaton_00071_V1T1_15_V1T1_29-V1T1_33_CAT.pdf
- Installation/Operator:
- Eaton_00231_INST.pdf
- Voltage Rating:
- 120/240 VAC
- Short Description:
- SPA PANEL 4 CKT 2P 40A GFCI SELF TEST 3R
- Current Rating:
- 40 A
- Enclosure Type:
- NEMA 3R, Outdoor
MSRP $940.00Surplus $380.67 -
Contact Us For Quote
Eaton CHP20L125R Loadcenters and Panelboards
MSRP $2,243.00Surplus $605.61SKU: L19-6608 Brand: Eaton MPN: CHP20L125R UPC: 78668905855 Shipping Weight: 0.00 lbs. Shipping Height: 0.00 In. Shipping Length: 0.00 In. Shipping Width: 0.00 In...- SKU:
- L19-6608
- Short Description:
- EATON CH MAIN LUG LOADCENTERS,COVER INCLUDED,MAIN LUG ONLY,125A,X2,COPPER,NEMA 3
- Circuit Configuration:
- 1-Phase 3-Wire
- Approval:
- UL 50/67
- Size:
- 14.3 Inch Width x 3.69 Inch Depth x 21 Inch Height
- Current Rating:
- 125 A
- Maximum Number of Spaces:
- (20) 3/4
- Bus Material:
- Silver Flash Plated Copper
- Neutral Type:
- Insulated/Bondable Split
- Catalog:
- Eaton_00071_V1T1_2-V1T1_33_CAT.pdf
- Feed Location:
- Overhead
- Main Wire Size:
- 6 to 2/0 AWG Copper/Aluminum
- Breaker Mounting:
- Plug-On
- Installation/Operator:
- Eaton_00231_INST.pdf
- Interrupting Rating:
- 25 kA
- Enclosure Type:
- NEMA 3R, Rainproof
- Type:
- Main Lug
- Enclosure Size Designation:
- X2
- Voltage Rating:
- 120/240 VAC
- Maximum Number of Circuits:
- 40
MSRP $2,243.00Surplus $605.61 -
Eaton CHP20L125X2 Loadcenters and Panelboards CH 125A 240V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1 Plug On Neutral
MSRP $463.00Surplus $62.14Eaton CHP20L125X2 Loadcenters and Panelboards CH 125A 240V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1 Plug On Neutral​ ARCA SKU: L19-1235 Brand: Eaton MPN: CHP20L125X2 UPC: 786689054250 Shipping Weight: 12...- SKU:
- L19-1235
- Type:
- Main Lug
- Approval:
- UL67
- Size:
- 14.31 Inch Width x 21 Inch Depth x 4 Inch Height
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 25 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Neutral Type:
- Insulated/Bondable Split
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Silver Flash Plated Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- X2
- Maximum Number of Spaces:
- 20
- Feed Location:
- Top/Bottom
- Main Wire Size:
- 6 to 2/0 AWG (Copper/Aluminum)
- Main Breaker Type:
- CH
- Breaker Mounting:
- Plug-On
- Short Description:
- 120/240 VAC, 1-Phase, 125 A, 3-Wire, 40-Circuit, 20-Space, Flush/Surface Cover, X2 Enclosure Size Designation, NEMA 1, Indoor, Sandalwood Painted 16 Gauge Sheet Steel Enclosure, Silver Flash Plated Copper Bus, Insulated/Bondable Split Plug-On Neutral
- Catalog:
- Eaton_46524_V1T1_2-V1T1_5_V1T1_9_CAT.pdf
- Current Rating:
- 125 A
- Enclosure Type:
- NEMA 1, Indoor
- Voltage Rating:
- 120/240 VAC
- Country of Origin:
- United States
MSRP $463.00Surplus $62.14 -
Eaton MBE2040PV125BTF Loadcenters and Panelboards EA
MSRP $3,221.87Surplus $317.71SKU: U00-3441 Brand: Eaton MPN: MBE2040PV125BTF UPC: 78668589463 Shipping Weight: 45.00 lbs. Shipping Height: 7.00 In. Shipping Length: 39.00 In. Shipping Width: 17...- SKU:
- U00-3441
- Type:
- Main Breaker
- Current Rating:
- 125 A
- Maximum Number of Circuits:
- 40
- Circuit Configuration:
- 1-Phase 3-Wire
- Maximum Number of Spaces:
- 20
- Main Breaker Type:
- BR
- Interrupting Rating:
- 22 kA
- Short Description:
- EATON BR METER BREAKER EUSERC SINGLE-PHASE 125A MAIN CIRCUIT BREAKER 225A BUS 40
- Series:
- MBE
- Country of Origin:
- United States
MSRP $3,221.87Surplus $317.71 -
GE TLM4020CCU Loadcenters and Panelboards 1P 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1
MSRP $473.00Surplus $148.69SKU: L19-1052 Brand: GE MPN: TLM4020CCU UPC: 783164112405 Shipping Weight: 37.00 lbs. Shipping Height: 5.50 In. Shipping Length: 41.25 In. Shipping Width: 16.00 In...- SKU:
- L19-1052
- Type:
- Standard
- Approval:
- UL
- Size:
- 39.2 Inch
- Amps:
- 32 A
- Interrupting Rating:
- 65 kA
- Enclosure:
- NEMA 1
- Circuit Configuration:
- 3-Wire
- Short Description:
- 120/240 VAC 1-Phase, 200 A, 22 kA, 3-Wire, 40-Circuit, 60-Space, 6 AWG to 250 KCMIL Copper/Aluminum, Top/Bottom Feed Location, Tin Plated Copper Bus, NEMA 1, Indoor, Convertible Main, Standard
- Catalog:
- ABBElectrificationProducts-ABBGEIndustrialSolutions_00018_1_9_1_10_1_32_CAT.pdf
- Enclosure Type:
- NEMA 1
- Current Rating:
- 200 A
- Maximum Number of Circuits:
- 40
- Voltage Rating:
- 120/240 VAC
- Country of Origin:
- United States
MSRP $473.00Surplus $148.69 -
Contact Us For Quote
Murray LC2040L1125 Loadcenters and Panelboards EA
MSRP $421.00Surplus $113.67Murray LC2040L1125 Loadcenters and Panelboards EA​ ARCA SKU: L19-3531 Brand: Murray MPN: LC2040L1125 UPC: 04089200962 Shipping Weight: 25.15 Shipping Height: 27.00 In. Shipping...- SKU:
- L19-3531
- Type:
- Main Lug
- Approval:
- UL
- Size:
- 14-3/8 Inch W x 4 Inch D x 24 Inch H
- Volts:
- 120/240 VAC
- Volts:
- 208 Star/120 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 65 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Insulated and Bonded Split
- Neutral Type:
- Solid
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Aluminum
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (20) 1 Inch
- Feed Location:
- Bottom
- Main Wire Size:
- 4 to 2/0 AWG (Copper/Aluminum)
- Main Breaker Type:
- MBK100M
- Main Breaker Type:
- MBK125M
- Short Description:
- 120/240 VAC, 125 A, 65 kA, 1-Phase, 3-Wire, 40-Circuit, 20-Space, Flush/Surface, Indoor, NEMA 1, Aluminum Bus
- Catalog:
- SiemensAG_00562_1_2_1_31_CAT.pdf
- Data Sheet:
- SiemensAG_06317_1_DATA.pdf
MSRP $421.00Surplus $113.67 -
Contact Us For Quote
Siemens LC2040B1200 Loadcenters and Panelboards 200A 240V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1 Surface/Flush Mounting
MSRP $963.00Surplus $403.76SKU: L19-1670 Brand: Siemens MPN: LC2040B1200 UPC: 040892009521 Shipping Weight: 31.20 lbs. Shipping Height: 4.90 In. Shipping Length: 31.70 In. Shipping Width: 15.80...- SKU:
- L19-1670
- Type:
- Main Breaker
- Size:
- 14-3/8 Inch W x 4 Inch D x 30 Inch H
- Volts:
- 120/240 V
- Amps:
- 32 A
- Interrupting Rating:
- 22000 A
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Neutral Type:
- Insulated
- Neutral Type:
- Bonded Split
- Circuit Configuration:
- 1-Phase
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- 20
- Main Wire Size:
- 4 AWG to 250 KCMIL
- Main Breaker Type:
- MQH/MD-H/MPP-HT
- Short Description:
- 120/240 VAC, 200 A, 22 KA, 1-Phase, 3-Wire, 40-Circuit, 20-Space, Flush/Surface, NEMA 1, Indoor, Aluminum Bus
- Catalog:
- SiemensAG_00562_1_2_1_31_CAT.pdf
- Data Sheet:
- SiemensAG_06314_1_DATA.pdf
- Enclosure Type:
- NEMA 1, Indoor
- Voltage Rating:
- 120/240 V
- Current Rating:
- 200 A
MSRP $963.00Surplus $403.76 -
Contact Us For Quote
Siemens P2040B1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1 Flush or Surface Mount Cover
MSRP $265.00Surplus $153.74Siemens P2040B1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1 Flush or Surface Mount Cover​ ARCA SKU: L19-1710 Brand: Siemens MPN: P2040B1200CU UPC: 040892650167 Shipping...- SKU:
- L19-1710
- Series:
- PL
- Type:
- Main Breaker
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch W x 3-7/8 Inch D x 30 Inch H
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 22 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (20) 1 Inch
- Feed Location:
- Bottom
- Short Description:
- 120/240 VAC, 200 A, 22 kA, 1-Phase, 3-Wire, 40-Circuit, 20-Space, Flush/Surface, NEMA 1, Indoor, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_33_CAT.pdf
- Data Sheet:
- SiemensAG_06844_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07796_1_CAD.pdf
- Voltage Rating:
- 120/240 VAC
- Current Rating:
- 200 A
- CAD Drawings:
- SiemensAG_07796_1_CAD.pdf
- Enclosure Type:
- NEMA 1, Indoor
MSRP $265.00Surplus $153.74 -
Contact Us For Quote
Siemens P2040L1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1
MSRP $160.50Surplus $88.26Siemens P2040L1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 20Sp NEMA 1​ ARCA SKU: L19-1711 Brand: Siemens MPN: P2040L1200CU UPC: 040892650174 Shipping Weight: 29.00 Shipping...- SKU:
- L19-1711
- Series:
- PL
- Type:
- Main Lug
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch W x 3-7/8 Inch D x 30 Inch H
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 100 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (20) 1 Inch
- Feed Location:
- Bottom
- Main Breaker Type:
- MBK150A
- Main Breaker Type:
- MBK200A
- Short Description:
- 120/240 VAC, 200 A, 100 kA, 1-Phase, 3-Wire, 40-Circuit, 20-Space, Flush/Surface, Indoor, NEMA 1, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_33_CAT.pdf
- Data Sheet:
- SiemensAG_06846_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07795_1_CAD.pdf
- CAD Drawings:
- SiemensAG_07795_1_CAD.pdf
- Voltage Rating:
- 120/240 VAC
- Current Rating:
- 200 A
- Enclosure Type:
- NEMA 1, Indoor
MSRP $160.50Surplus $88.26 -
Contact Us For Quote
Siemens P2440L1125CU Loadcenters and Panelboards 125A 120V 50/60Hz 1Ph 3Wire 40Cir 24Sp NEMA 1 Surface/Flush Mounting
MSRP $143.00Surplus $78.67Siemens P2440L1125CU Loadcenters and Panelboards 125A 120V 50/60Hz 1Ph 3Wire 40Cir 24Sp NEMA 1 Surface/Flush Mounting​ ARCA SKU: L19-1697 Brand: Siemens MPN: P2440L1125CU UPC: 040892649765 Shipping...- SKU:
- L19-1697
- Series:
- PL
- Type:
- Main Lug
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch Width x 3-7/8 Inch Depth x 24 Inch Height
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 100 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (24) 1 Inch
- Feed Location:
- Bottom
- Main Breaker Type:
- MBK100A
- Main Breaker Type:
- MBK125A
- Short Description:
- 120/240 VAC, 125 A, 100 kA, 1-Phase, 3-Wire, 40-Circuit, 24-Space, Flush/Surface, Indoor, NEMA 1, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_33_CAT.pdf
- Data Sheet:
- SiemensAG_06848_1_DATA.pdf
MSRP $143.00Surplus $78.67 -
Contact Us For Quote
Siemens P3040B1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 30Sp NEMA 1 Flush or Surface Mount Cover
MSRP $312.00Surplus $171.83Siemens P3040B1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 30Sp NEMA 1 Flush or Surface Mount Cover​ ARCA SKU: L19-1748 Brand: Siemens MPN: P3040B1200CU UPC: 040892650433 Shipping...- SKU:
- L19-1748
- Series:
- PL
- Type:
- Main Breaker
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch Width x 3-7/8 Inch Depth x 36 Inch Height
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 22 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (30) 1 Inch
- Feed Location:
- Bottom
- Short Description:
- 120/240 VAC, 200 A, 22 kA, 1-Phase, 3-Wire, 40-Circuit, 30-Space, Flush/Surface, NEMA 1, Indoor, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_33_CAT.pdf
- Data Sheet:
- SiemensAG_06859_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07802_1_CAD.pdf
- Current Rating:
- 200 A
- Enclosure Type:
- NEMA 1, Indoor
- CAD Drawings:
- SiemensAG_07802_1_CAD.pdf
- Voltage Rating:
- 120/240 VAC
MSRP $312.00Surplus $171.83 -
Contact Us For Quote
Siemens P3040L1125CU Loadcenters and Panelboards 125A 120V 50/60Hz 1Ph 3Wire 40Cir 30Sp NEMA 1
MSRP $153.50Surplus $75.35Siemens P3040L1125CU Loadcenters and Panelboards 125A 120V 50/60Hz 1Ph 3Wire 40Cir 30Sp NEMA 1​ ARCA SKU: L19-1699 Brand: Siemens MPN: P3040L1125CU UPC: 040892650440 Shipping Weight: 37.00 Shipping...- SKU:
- L19-1699
- Series:
- PL
- Type:
- Main Lug
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch W x 3-7/8 Inch D x 30 Inch H
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 100 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (30) 1 Inch
- Feed Location:
- Bottom
- Main Breaker Type:
- MBK100A
- Main Breaker Type:
- MBK125A
- Short Description:
- 120/240 VAC, 125 A, 100 kA, 1-Phase, 3-Wire, 40-Circuit, 30-Space, Flush/Surface, Indoor, NEMA 1, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_33_CAT.pdf
- Data Sheet:
- SiemensAG_06860_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07805_1_CAD.pdf
MSRP $153.50Surplus $75.35 -
Contact Us For Quote
Siemens P3040L1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 30Sp NEMA 1 Surface/Flush Mounting
MSRP $196.50Surplus $108.39Siemens P3040L1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 30Sp NEMA 1 Surface/Flush Mounting​ ARCA SKU: L19-1732 Brand: Siemens MPN: P3040L1200CU UPC: 040892650464 Shipping...- SKU:
- L19-1732
- Series:
- PL
- Type:
- Main Lug
- Type:
- Convertible
- Approval:
- UL 50/67/486/489/869/943
- Size:
- 14.25 Inch Width x 3.88 Inch Depth x 36 Inch Height
- Volts:
- 120/240 VAC 1-Phase 3-Wire
- Amps:
- 32 A
- Interrupting Rating:
- 100 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Insta-Wire
- Neutral Type:
- Dual
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (30) 1 Inch
- Short Description:
- 120/240 VAC, 200 A, 100 kA, 1-Phase, 3-Wire, 40-Circuit, 30-Space, Flush/Surface, Indoor, NEMA 1, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_33_CAT.pdf
- Data Sheet:
- SiemensAG_06862_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07805_1_CAD.pdf
- Voltage Rating:
- 120/240 VAC 1-Phase 3-Wire
- Enclosure Type:
- NEMA 1, Indoor
- CAD Drawings:
- SiemensAG_07805_1_CAD.pdf
- Current Rating:
- 200 A
MSRP $196.50Surplus $108.39 -
Contact Us For Quote
Siemens P4040B1200 Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1 Flush or Surface Mount Cover
MSRP $355.00Surplus $195.23Siemens P4040B1200 Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1 Flush or Surface Mount Cover​ ARCA SKU: L19-1035 Brand: Siemens MPN: P4040B1200 UPC: 040892650501 Shipping...- SKU:
- L19-1035
- Series:
- PL
- Type:
- Main Breaker
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch W x 3-7/8 Inch D x 36 Inch H
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 22 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Aluminum
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (40) 1 Inch
- Feed Location:
- Bottom
- Main Wire Size:
- 3/0 AWG (Copper)
- Main Wire Size:
- 250 KCMIL (Aluminum) (Main Breaker)
- Short Description:
- 120/240 VAC, 200 A, 22 kA, 1-Phase, 3-Wire, 40-Circuit, 40-Space, Flush/Surface, NEMA 1, Indoor, Aluminum Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_34_CAT.pdf
- Data Sheet:
- SiemensAG_06876_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07802_1_CAD.pdf
- Voltage Rating:
- 120/240 VAC
- Enclosure Type:
- NEMA 1, Indoor
- CAD Drawings:
- SiemensAG_07802_1_CAD.pdf
- Current Rating:
- 200 A
MSRP $355.00Surplus $195.23 -
Contact Us For Quote
Siemens P4040B1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1
MSRP $369.00Surplus $208.73Siemens P4040B1200CU Loadcenters and Panelboards 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1​ ARCA SKU: L19-1038 Brand: Siemens MPN: P4040B1200CU UPC: 040892650518 Shipping Weight: 39.44 Shipping...- SKU:
- L19-1038
- Series:
- PL
- Type:
- Main Breaker
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch Width x 3-7/8 Inch Depth x 36 Inch Height
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 22 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (40) 1 Inch
- Feed Location:
- Bottom
- Main Wire Size:
- 3/0 AWG (Copper)
- Main Wire Size:
- 250 KCMIL (Aluminum) Main Breaker
- Short Description:
- 120/240 VAC, 200 A, 22 kA, 1-Phase, 3-Wire, 40-Circuit, 40-Space, Flush/Surface, NEMA 1, Indoor, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_34_CAT.pdf
- Data Sheet:
- SiemensAG_06877_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07803_1_CAD.pdf
- Current Rating:
- 200 A
- CAD Drawings:
- SiemensAG_07803_1_CAD.pdf
- Enclosure Type:
- NEMA 1, Indoor
- Voltage Rating:
- 120/240 VAC
MSRP $369.00Surplus $208.73 -
Contact Us For Quote
Siemens P4040L1200CU Loadcenters and Panelboards 2P 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1 Surface/Flush Mounting
MSRP $283.00Surplus $164.03Siemens P4040L1200CU Loadcenters and Panelboards 2P 200A 120V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1 Surface/Flush Mounting​ ARCA SKU: L19-1778 Brand: Siemens MPN: P4040L1200CU UPC: 040892650556 Shipping...- SKU:
- L19-1778
- Series:
- PL
- Type:
- Main Lug
- Type:
- Convertible
- Approval:
- UL
- Size:
- 14-1/4 Inch Width x 3-7/8 Inch Depth x 36 Inch Height
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 100 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Bonded
- Neutral Type:
- Groundable
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Enclosure Size Designation:
- 1
- Maximum Number of Spaces:
- (40) 1 Inch
- Feed Location:
- Bottom
- Main Breaker Type:
- MBK150A
- Main Breaker Type:
- MBK200A
- Short Description:
- 120/240 VAC, 200 A, 100 kA, 1-Phase, 3-Wire, 40-Circuit, 40-Space, Flush/Surface, Indoor, NEMA 1, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2_1_12_1_34_CAT.pdf
- Data Sheet:
- SiemensAG_06880_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07812_1_CAD.pdf
- Voltage Rating:
- 120/240 VAC
- Enclosure Type:
- NEMA 1, Indoor
- Current Rating:
- 200 A
- CAD Drawings:
- SiemensAG_07812_1_CAD.pdf
MSRP $283.00Surplus $164.03 -
Contact Us For Quote
Siemens PN4040B1200C Loadcenters and Panelboards 200A 240V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1
MSRP $740.00Surplus $199.80Siemens PN4040B1200C Loadcenters and Panelboards 200A 240V 50/60Hz 1Ph 3Wire 40Cir 40Sp NEMA 1​ ARCA SKU: L19-2016 Brand: Siemens MPN: PN4040B1200C UPC: Shipping Weight: 39.80 Shipping...- SKU:
- L19-2016
- Type:
- Main Breaker
- Approval:
- UL
- Volts:
- 120/240 VAC
- Amps:
- 32 A
- Interrupting Rating:
- 22 kA
- Enclosure:
- NEMA 1
- Enclosure:
- Indoor
- Cover Type:
- Flush/Surface
- Neutral Type:
- Plug-On
- Circuit Configuration:
- 1-Phase 3-Wire
- Bus Material:
- Copper
- Maximum Number of Circuits:
- 40
- Maximum Number of Spaces:
- (40) 1 Inch
- Short Description:
- 120/240 VAC, 200 A, 22 kA, 1-Phase, 3-Wire, 40-Circuit, 40-Space, Flush/Surface, NEMA 1, Indoor, Copper Bus, Convertible
- Catalog:
- SiemensAG_00562_1_2-1_6_1_12_1_31_1_34_CAT.pdf
- Data Sheet:
- SiemensAG_06921_1_DATA.pdf
- CAD Drawing:
- SiemensAG_07837_1_CAD.pdf
MSRP $740.00Surplus $199.80
Disclaimer: ARCA Supply is not an authorized distributor, reseller or representative of any manufacturer, brand or product listed. All product names, trademarks, brands and logos are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder. All items sold by ARCA Supply are covered under ARCA Supply's warranty and not the manufacturer warranty.